Volume 1
MIL-HDBK- 162A
Section 1
15 December 1965
ITEM NAME: CONTROL-MONITOR GROUP
TYPE: AN/FSA--1A
ph, :3718 w
transmitters.
INSTALLATION CONSIDERATIONS
RELATION TO SIMILAR EQUIPMENT
The AN/FSA-4A is interchangeable with the
Siting: Equipment Is Installed in
AN/FSA-.4, the difference Is the AN/FSA-.4A has a
Control Center Building.
lockout feature and an automatic visual Identification of
Incoming signals.
Mounting: Consoles are bolted to the floor.
TECHNICAL DESCRIPTION
Input is 117v, 60 cps, single or three
PRINCIPAL COMPONENTS AND PHYSICAL DATA
COMPONENT
QTY
HEIGHT
WIDTH
DEPTH
UNIT WT.
(Inches)
(Inches)
(Inches)
(Pounds)
6
43-1/8
21-9/32
45
199
OR -93-1/FSA-4A
Communi4cations Control Console
2
43-1/8
31-27/32
45
OA-937/FSA-1A
1
43-1/8
21-9/32
45
OA-938/FSA-4A
1
43-1/8
21-9/32
45
93
OA-9:39/FSA-.1A
Interconnecting Group
2
76
22
38
354 .5
OA-447/FSA- 1
Interconnecting Group
1
76
22
38
459.5
OA -935/FSA-. 1A
Interconnecting Group
1
76
22
38
319.5
OA -936 /FSA-. 1A
1
76
22
38
518.5
Group OA-9-12/FSA-.1A
1
76
22
38
518.5
Group OA-9.13/FSA-.1A
Power Supply Group
1
76
22
21
OA -941/FSA-.1A
1
76
22
38
604.5
OA-940/FSA- 1A
REFERENCE DATA AND LITERATURE
TECHNICAL ORDERS:
31S1-2FSA4 - Series
AN/FSA-4A: 2