Volume 1
MIL-HDBK-162A
Section 1
15 December 1965
ITEM NAME: HEIGHT-RANGE DATA CONVERTER
TYPE: CV-601/FPS-6A
line) without consideration of the variable refractive
Range - 1000 ohms
index. The CV-601/FPS-6A provides a compensated,
Height - 5000 ohms
integrated height-line voltage for direct application to the
Gear Train Response Time: Not greater than 3 sec
The
from limit to limit
OA-929/FPS-6A receives height, range, and correction
INSTALLATION CONSIDERATIONS
itself. A switch, set at the time of initial installation,
selects the proper OA-929/FPS-6A output.
Siting: Dependent on associated radar.
RELATION TO SIMILAR EQUIPMENT
Mounting: Dependent on associated radar.
None.
Cabling Requirements:
TECHNICAL DESCRIPTION
4 height line voltage cables
4 range voltage cables
Range Input: -0.566v dc per mi
1 power cable
Height Input: 0.226v dc per 1000 ft
1 grounding wire
Power Input: 115v, 60 cps, 1-ph
Related Equipment:
OA-929/FPS-6A Output Voltages:
Height Voltage - -2.2v dc per 1000 ft
1 Indicator Group OA-929/FPS-6A
1 Radar Set Group OA-270/FPS-6
Range Voltage - 0.733v dc per mi
1 Radar Set Group OA-1010/GPS
OA-270/FPS-6 Output Voltages:
1000 ft
PRINCIPAL COMPONENTS AND PHYSICAL DATA
COMPONENT
QTY
HEIGHT
WIDTH
DEPTH
UNIT WT.
(Inches)
(Inches)
(Inches)
CV-601/FPS-6A
1
12.68
13.28
25.5
REFERENCE DATA AND LITERATURE
Technical Orders:
31P3-2FPS6-151
31P3-2FPS6-153
31P3-2FPS6-154
31P3-2FPS6-575
CV-601/FPS-6A: 2