Volume 1
MIL-HDBK-162A
Section 2
15 December 1965
ITEM NAME: PULSE ANALYZER GROUP
TYPE: AN/APA-64, AN/APA-64A
12 uw
to the correct meter reading.
Accuracy: plus or minus 5% for all pulse
widths and prf's
RELATION TO SIMILAR EQUIPMENT
Video Sensitivity: 1.5v
None.
INSTALLATION CONSIDERATIONS
TECHNICAL DESCRIPTION
Related Equipment: (Equipment Required
Pulse Durations: 0.5 to 20 usec
but not Supplied) (1) Receiver AN/APR-1
Repetition Frequencies: 50 to 5000 cps
or (1) Receiver AN/APR-4, or (1) Re-
Video Input Amplitude: 1.5 to 10v, either
ceiver AN/APR-SA, or (1) Receiver AN/
positive or negative
APR-9, (1) Power Supply, (1) Cable
Operating Power: 109 to 119v, single ph,
RG-58/U, (1) Cable.
380 to 1760 cps, and 25 to 29.5v dc,
PRINCIPAL COMPONENTS AND PHYSICAL DATA
COMPONENT
QTY
HEIGHT
WIDTH
DEPTH
UNIT WT.
(Inches)
(Inches)
(Inches)
(Pounds)
Indicator Connate
1
3-1/8
4-1/2
6
2.5
ID-228A/APA-64
Pulse Analyzer RF-38A/APA-64
1
7-5/8
5-5/16
19-3/4
17.0
or RF-33B/APA-64
REFERENCE DATA AND LITERATURE
Technical Manuals:
Specifications:
NAVAER 16-30APA64-12
RE-16A44(Aer)
NAVAER 16-30APA64-501
AN/APA-64: 2