Volume 1
MIL-HDBK-162A
Section 2
15 December 1965
ITEM NAME: RADAR TRAINING SET
TYPE: AN/UPT-T4
Power Requirements: 115v plus or minus 10%, 60 cps,
the information presented by radar systems.
1-ph, 45Ow, 90% pf
RELATION TO SIMILAR EQUIPMENT
INSTALLATION CONSIDERATIONS
None.
Related Equipment
Required but not Supplied
TECHNICAL DESCRIPTION
(1) Antenna (AS-263/UPT for directional use),
(1) Test Meter I-139-A, (1) Frequency Meter of
Frequency Range: 175 to 550 me
Calibrated Receiver to cover desired operating
Power Output: 7 to 30w
Modulation Capability
168/AP with Control Box C-157/AP or other RF
Noise: Sidebands approx 7 mc, 3.5 mc ea side of
output indicator, Power Cable as Required,
carrier.
Sine Wave: Approx 65% modulation can be
obtained.
PRINCIPAL COMPONENTS AND PHYSICAL DATA
COMPONENTS
QTY
OVERALL DIMENSIONS
UNIT WT.
(Inches)
(Pounds)
1
7-11/16 x 10-3/8 x 21-5/32
48
Power Supply F3805
1
7-11/16 x 10-3/8 x 21-5/32
71
Mounting Base MT-171/U
2
2-1/8 x 11-3/8 x 25-9/16
2
Cable with Plugs
3
36 lg
1.17
RF Plug UG-21/U
1
5/8 dia x 1-5/8
0.2
RF Adapter UG-27/U
1
3/4 x 1-1/2 x 1-1/2
0.2
Plug AN31OB-22-4S
1
0.5
REFERENCE DATA AND LITERATURE
Handbook of Maintenance Instructions for
AN/UPT-T4: 2