Volume 1
MIL-HDBK-162A
Section 3
15 December 1965
ITEM NAME: RANGE INDICATOR
TYPE: IP-99/SP, IP-99A/SP
Scan: 5 in. A-Scope
is received. The time interval! between the main bang
and the target pip is proportional to the distance
Ambient Temperature: -20OC to plus 65OC
between the radar set and the left-hand origin of the
Power Source Required
trace is proportional to the time interval, the trace can
IP-99/SP: 115v, 60 cps, i-ph, 100w
be calibrated for the direct measurement of the target
IP-99A/SP: 115v, 60 cps, 1-ph, 200w
range.
INSTALLATION CONSIDERATIONS
RELATION TO SIMILAR EQUIPMENT
Related Equipment:
Required but not Supplied. (1) Radar Set, (as
None.
required) Cable, Coaxial RG-10/U, (as required)
Cable, Coaxial RG-12/U, (as required) Cable,
TECHNICAL DESCRIPTION
Single Conductor SHFA-3, (as required) Cable,
Double Conductor DHFA-3.
Sweep Ranges: 4, 20, 80, and 200 mi
PRINCIPAL COMPONENTS AND PHYSICAL DATA
SHIPPING DATA
COMPONENT
BOXES
OVERALL DIMENSIONS
UNIT WT.
(NR)
(Inches)
(Pounds)
IP-99/SP
Range Indicator IP-99/SP
1
20 x 20 x 33
174.0
Visor Hood
1
7 x 7 x 13
8.0
Tubes
1
8 x 16 x 16
10.0
Maintenance Spares
1
13 x 13-1/2 x 14-1/2
90.0
IP-99A/SP
Range Indicator IP-99A/SP
1
26 x 27 x 39
250
CR Tube and Visor Hood
1
19-7/8 x 19-7/8 x 26-1/2
56
EQUIPMENT SUPPLIED DATA
COMPONENTS
QTY
OVERALL DIMENSIONS
UNIT WT.
IP-99/SP IP-99A/SP
(Inches)
(Pounds)
Range Indicator IP-99/SP
1
17 x 18 x 32
150
Range Indicator IP-99A/SP
1
17 x 18 x 32
160
Visor Hood
1
1
5-7/8 x 6-1/4 x 12-5/16
2.0
Technical Manual
2
4
Box Maintenance Spares
1
12 x 12 x 12
75
Set Maintenance Prints
1
2
Set Test Data
1
1
9
Set Tubes
1
P-99/SP: 2