TM 11-5840-208-30-1
CHECK
PARA
PAGE
b.
Radiate light. After 5-minutes or sufficient
time depending upon differences among sets.
3-48
52
c.
magnetronvariac for 18 MA on magnetron current
meter.
3-48, 3-49,
3-50
52
3-9. COMPUTER SYSTEM
a.
Elevation and "C" dial should move when the
antenna is moved in elevation. Leave at +70 mils
("C" dial should read 2. 0) (A handwheels detented
& time 0. 0, & weapon height same as radar height)
3-38
48
b.
Azimuth. Moving the antenna in azimuth should
move EW, NW and AZW dials.
3-39
48
c.
"C" dial With the antenna set to +35 mils the
"C" dial should read 1. 0, +70 mils "C" dial should
read 2. 0 with test normal switch in NORMAL. When
test normal switch is in test "C" dial should read 1. 0.
3-45
49
Range counter. RL and AR handwheels should
d.
move the range strobe, EW, NW, RW, and "C" dial
3-40
48
e.
Delta azimuth. Delta azimuth handwheel should
move the azimuth strobe, EW, NW, and AZW counter.
3-40
48
f.
A Height. Should move height counter and "C"
dial.
3-42
49
g.
Delta time. Should move time counter and "C"
dial.
3-42
49
Page 29