TM 11-5840-281-12-1
2-11. STANDBY CONDITION. (CONT)
To place the radar set in standby, perform the following on master and slave control indicators:
1. Place TRANSMITTER switch (1) on master to OFF position.
2. Place SCAN switch (2) on master to OFF position.
3. Rotate INTENSITY controls (3) on both control-indicators to fully counterclockwise position.
2-12. NORMAL SHUTDOWN.
To completely turn off the radar set, perform the following on master and slave control indicators:
1. Place SCAN switch (1) on master to OFF position.
2. Place TRANSMITTER switch (2) on master to OFF position.
3. Rotate INTENSITY controls (3) on both control-indicators to full CCW position.
4. Place POWER circuit breakers (4) on both control-indicators to OFF position.
5. Place MAIN PWR circuit breaker (5) to OFF position.
6. Close air vent (6) on receiver door (7).
2-33