TM 11-5840-281-12-1
4-32. ORGANIZATIONAL TROUBLESHOOTING. (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5.
No radar video and HV ON indicator switch on either control-indicator is not illuminated. Antennas do not scan or
scan erratically. (CONT)
Step 2.
Place MONITOR switch to - 35V position and observe MONITOR meter Indication.
a. If meter indicates - 35 v, proceed to step 3.
b. If meter indicates 0 v, replace 35V voltage regulator card (para 4-39) and
perform receiver-transmitter power supply adjustments (para 4-41).
c.
If meter indicates other than - 35 v, adjust 35V voltage regulator card as
indicated in 1 through 3.
1.
2.
Connect negative lead of multimeter to J5303 VOLTAGE MON and
connect positive lead to J5304 GND on local control monitor.
3.
Adjust R3427 - 35 ADJ on 35V voltage regulator card for multimeter
indication of - 35 v.
If adjustment in 1 through 3 cannot be accomplished, replace 35V low voltage
regulator card (para 4-39) and perform receiver-transmitter power supply
Step 3.
On local control monitor, place MONITOR switch to + 28V position and observe MONITOR meter
Indication.
If MONITOR meter does not indicate + 28 + 4 v, replace rectifier card (para 4-
39) and perform receiver-transmitter power supply adjustments (para 4-41).
Step 4.
Perform the voltage checks in the table below at the transmitter control unit. MULTIMETER
TESTPOINT CONNECTION
POSITIVE LEAD
NEGATIVE LEAD
INDICATION
+28 4.0 V
J141 + 28 V
J139 LVPS COM
J140 + 12 V
J139 LVPS COM
+ 12 0.6 V
- 19 1.5 V
J139 LVPS COM
J137 - 19 V
J139 LVPS COM
J138 -6V
4-110