4-34. DESCRIPTION OF MAINTENANCE CONTROLS, INDICATORS, AND SWITCHES. (CONT)
CONTROL-INDICATOR
KEY
CONTROL OR INDICATOR
DESCRIPTION
1
R1632 + 300V ADJ
Adjusts positive output of rotating coil amplifier regulator.
2
R2201 IFF VIDEO ADJ
Adjusts IFF video output signal from mixer amplifier card.