TM 11-5840-281-12-1
4-34. DESCRIPTION OF MAINTENANCE CONTROLS, INDICATORS, AND SWITCHES. (CONT)
KEY
CONTROL OR INDICATOR
DESCRIPTION
16
MAGNETRON EXCESS
Illuminates when magnetron arcing (sparking) occurs.
SPARKING indicator
17
POWER SUPPLY OVLD
Illuminates when high-voltage power supply current over-
Indicator
load occurs.
18
CHARGING OVLD indicator
Illuminates when pfn charging overload occurs.
19
TRIGGER SELECT INTERNAL-
Two-position indicator switch allows selection of
EXTERNAL indicator switch
internally generated trigger or externally generated
20
CIRCUIT SELECT
Two-position indicator switch allows application of
MAGNETRON-MODULE
test signals to magnetron fault circuits or modulator
indicator switch
fault circuits when TEST indicator switch is in ON
position.
21
TEST ON-OFF indicator
When ON section is depressed, allows test signals to be
switch
applied to fault circuits.
4-128