TM 11-5840-281-35/1
Control settings
Step No.
Test equipment
Equipment under test
Test procedure
Performance standard
As last indicated, except:
a.
a. +0.4v on differential
On Pulse Generator
Pulse Generator
5 As last indicated, except:
0-1333/
voltmeter.
O-15S/rTPN-18
Differential voltmeter
TPN-18 adjust ANGLE
under test
A: 0
VOLTS control for +0.4v
ANGLE VOLTS
B: 4
indication on differential volt-
control: 020
C: 0
meter as NULL switch is
D: 0
placed from 10 to 1 and from
E: 0
1 to .1.
b. 14 min, 26 max.
b. Observe setting of ANGLE
VOLTS control dial.
As last indicated, except:
+0.12v max.
Pulse Generator
6 As last indicated, except:
O-13S$/TPN-18
Differential voltmeter
adjust
under test
RANGE: .5
A,B,C,D, and E switches for
ANGLE VOLTS
null indication on meter and
control: 000
observe voltage indicated by
A,B,C,D, and E switches.
As last indicated, except:
Pulse Generator
7 As last indicated-..
+0.09v max.
0-15$/TPN- 18
under test
adjust
ANGLE VOLTS
A,B,C,D, and E switches for
switch: AZ
null indication on meter and
observe voltage indicated by
As last indicated, except:
A,B,C,D, and E switches.
a. +2.25v on differential
Pulse Generator
voltmeter.
O-15S3/TPN-18
8 As last indicated, except:
under test
Differential voltmeter
a.
ANGLE VOLTS
RANGE: 5
TPN-18 under test,
control: 075
A: 2
adjust
B: 2
ANGLE VOLTS control for
C: 5
b. 72 min, 78 max.
+2.25 indication on differential
D: 0
voltmeter as NULL switch is
E: 0
placed from 10 to 1 and from
As last indicated, except:
1 to .1.
a. +4.5v on differential
Pulse Generator
b. Observe setting of ANGLE
voltmeter.
O-ISTPN-1 8
9 As last indicated, except:
VOLTS control dial.
under test
Differential voltmeter
ANGLE VOLTS
A: 4
TPN-18 adjust ANGLE
control: 150
B: 5
VOLTS control for +4.5v
C: 0
indication on differential volt-
D: 0
b. 147 min, 153 max.
meter as NULL switch is
E: 0
placed from 10 to 1 and from
1 to .1.
As last indicated, except:
b. Observe setting of ANGLE
a. +6.75v on differential
Pulse Generator
VOLTS control dial.
voltmeter.
0-13355/ TPN-18
10 As last indicated, except:
under test
Differential voltmeter
ANGLE VOLTS
RANGE: 50
a.
control: 225
A: 0
TPN-18 under test, adjust
B: 6
ANGLE VOLTS control for
C:7
b.
222 min, 228 max.
+6.75v indication on differential
D: 5
voltmeter as NULL switch is
E: 0
placed from 10 to 1 and from
As last indicated, except:
a. +9v on differential
1 to .1.
Pulse Generator
voltmeter.
b.
Observe setting of ANGLE
0-1553/ TPN-I 8
11 As last indicated, except:
VOLTS control dial.
under test
A: 0
ANGLE VOLTS control:
B: 9
a.
300
C: 0
TPN-18 under test, adjust
D: 0
ANGLE VOLTS control for
E: 0
b. 297 min, 303 max.
+9v indication on differential
voltmeter as NULL switch is
c. None.
placed from 10 to 1 and from 1
to .1.
b.
Observe setting of ANGLE
VOLTS control dial.
c.
Disconnect differential volt-
meter test leads
4-42