TM 11-5840-281-35/1
Control settings
Step No.
Test equipment
Equipment under test
Test procedure
Performance standard
B
167 max, 157 min.
b. Observe setting of ANGLE
VOLTS control dial.
a. None.
14
...............................As last indicated
a. On Pulse Generator 0-1333/
TPN-18 under test, adjust
ANGLE VOLTS control to
position cursor dot on 5-mi
range mark on artificial azimuth
sweep.
b. 164 max, 164 min.
b. Observe setting of ANGLE
VOLTS control dial.
15
...............................As last indicated -
a. None.
a. On Pulse Generator 0-1333/
TPN-18 under test, adjust
ANGLE VOLTS control to
position cursor dot on 6-mi
range mark on artificial azimuth
sweep.
b. 163 max, 153 min.
b. Observe setting of ANGLE
VOLTS control dial.
16
...............................As last indicated
a. None.
O-1333/TPN-18 under test,
place CURSOR SELECT
switch to 2 and RUNWAY
switch to L.
b. None.
b. Set ANGLE VOLTS control
to 197.
c. None.
O-1333/TPN-18, adjust
OFF-SET 2 control R1123 to
position cursor dot on 1-mi
range mark on artificial azimuth
sweep.
d. None.
d. Set ANGLE VOLTS control
to 158.
e. None.
0-1333/TPN-18, adjust
COURSE LINE 2 control
R1127 and CL VER 2 control
R1144 to position cursor dot on
6-mi range mark on artificial
azimuth sweep.
f. Repeat steps b thru d until
f.
None.
cursor dot is positioned on 1-mi
range mark with ANGLE VOLTS
control set at 197 and posi-
tioned on 6-mi-range mark with
ANGLE VOLTS control set at
158 without readjustment of
OFF-SET 2 control R1123 and
COURSE LINE 2 control
R1127.
17..
...............................As last indicated, except:
No appreciable difference
0-1333/TPN-18, place
between courseline cursor
0-1333/TPN-18
CURSOR SELECT switch
2 and courseline cursor 1
under test
S1104 back and forth to positions
(cursor 2 should be
ANGLE VOLTS switch:
I and 2 while observing course-
superimposed on cursor 1).
OPERATE
line cursor 1 and courseline
cursor 2 on azimuth scan.
O-01333/ TPN-18
SCAN: ON
4-56