Page Navigation
  31    32    33    34    35  36  37    38    39    40    41  
TM 11-5840-281-12-1
Section III OPERATION UNDER USUAL CONDITIONS
Subject
Para
Page
Assembly and Preparation for Use ....................................................................
2-3
2-10
Preliminary Control Settings ..............................................................................
2-4
2-10
Preliminary Operating Procedure .......................................................................
2-5
2-13
Search Operation ..............................................................................................
2-6
2-21
Precision Approach Operation ..........................................................................
2-7
2-25
Height Finder Operation .....................................................................................
2-8
2-28
Simultaneous Mode Operation ..........................................................................
2-9
2-29
IFF Operation.....................................................................................................
2-10
2-31
Standby Condition ............................................................... ...............................
2-11
2-32
Normal Shutdown............................................................... ................................
2-12
2-33
Emergency Shutdown ................................................ ........................................
2-13
2-34
2-3. ASSEMBLY AND PREPARATION FOR USE.
All assembly and preparation for use Is done by organizational maintenance personnel.
2-4. PRELIMINARY CONTROL SETTINGS.
RECEIVER-TRANSMITTER
1.
Place MAIN PWR circuit breaker (1) to OFF position.
2.
Place AC OUTLETS circuit breaker (2) to OFF position.
3.
Place HV switch (3) to OFF position.
4.
Place SCAN switch (4) to OFF position.
2-10