Volume 1
MIL-HDBK-162A
Section 3
15 December 1965
ITEM NAME: TRIGGER PULSE AMPLIFIER
TYPE: AM-1913B/UP
Delay: 0.5 to 2.5 usec can be made be-
RELATION TO SIMILAR EQUIPMENT
tween input and output signals
Power Supply Assy
None.
Input: 115v, 60 cyc, 1-ph, 33w
Output: 1O5v dc (B plus); 6.3v, 60
TECHNICAL DESCRIPTION
cyc, 1-ph (fill)
Ambient Temperature
Trigger Pulse Amplifier Input Signal
Storage: -62 to plus 750C (-79 to
plus 1670F)
Pulse Polarity: Pos
Operating: 0 to plus 500C (plus 32
Peak Pulse Amplitude: 5.0 to 55v max
to plus 1220F)
Duration: 0.3 to 25 usec
Repetition Rate: 10 to 5000 pps
INSTALLATION CONSIDERATION
Trigger Regenerator Output Signal
Not available.
Pulse Polarity: Pos
Peak Pulse Amplitude: 20 plus or minus 5v
Duration: 2 to 5 usec
Repetition Rate: 10 to 5000 pps
PRINCIPAL COMPONENTS AND PHYSICAL DATA
COMPONENT
QTY
OVERALL DIMENSIONS
UNIT WT.
(Inches)
(Pounds)
Trigger Pulse Amplifier
1
8-13/16 x 9-5/8 x 12
13
AM-1913B/UP
SHIPPING DATA
COMPONENT
PKGS
VOLUME (CU FT)
UNIT WT.
(Pounds)
1
18.1
17
REFERENCE DATA AND LITERATURE
Technical Manuals:
NAVSHIPS 95760
AM-1913B/UP: 2