Volume 1
MIL-HDBK-162 A
Section 3
15 December 1965
ITEM NAME: TRIGGER PULSE AMPLIFIER
TYPE: AM-1913/UP
Pulse Polarity: Pos
RELATION TO SIMILAR EQUIPMENT
Peak Pulse Amplitude: 20 plus or minus 5v
Duration: 2 to 5 usec at 50% nom peak
None.
Rise Time: 0.2 usec or less
Delay: 0.5 to 2.5 usec can be made be-
TECHNICAL DESCRIPTION
tween the input and output signals
Power Supply Assy
Trigger Pulse Amplifier Input Signal
Input: 115v, 60 cyc, 1-ph
Output: 105v dc (B plus); 6.3v, 60 cyc,
(output)
1-ph (fil)
Pulse Polarity: Pos
Peak Pulse Amplitude: 10v min
INSTALLATION CONSIDERATION
Repetition Rate: 20 to 4100 pps
Trigger Regenerator Output Signal
Not available.
(output)
PRINCIPAL COMPONENTS AND PHYSICAL DATA
COMPONENT
QTY
OVERALL DIMENSIONS
UNIT WT.
(Inches)
(Pounds)
Trigger Pulse Amplifier
1
8-3/16 x 9-1/2 x 11-7/8
19
AM-1913/UP
SHIPPING DATA
COMPONENT
PKGS
OVERALL DIMENSIONS
UNIT WT.
(Inches)
(Pounds)
1
18.
1 28
REFERENCE DATA AND LITERATURE
Technical Manuals:
NAVSHIPS 93222
AM-1913/UP: 2