TM 11-5840-208-30-1
Chart I . AN/MPQ-4A Computer Accuracy Check
TEST NORMAL SWITCH IN TEST
TEST NORMAL SWITCH IN NORMAL
M
t
HW
RL
AZ
EL
R
A
RW
AZW
EW
NW
C
1
0
863
2000
0
-50
100
0
2055
0
0
2055
0. 55
2
0
863
3000
200
-35
100
5
3033
202
596
2974
0.33
3
0
1000
5000
800
35
100
20
5104
821
3682
3535
1.04
4
0
1000
2500
1600
50
200
0
2855
1600
2855
0000
1.78
5
0
1000
2500
2000
50
400
-10
3437
1977
3311
99077
2. 34
6
0
1000
2500
2400
50
-100
-20
2370
2374
1718
98368
1.31
7
0
1000
2500
2800
50
-300
-30
2168
2767
894
98026
1.11
8
0
954
2500
3200
50
100
15
2718
3233
99913
97283
2.18
9
0
908
2500
3200
50
100
15
2776
3241
99887
97226
2. 76
10
0
1092
2500
3200
50
100
15
2541
3206
99984
97459
0. 41
11
2.0
1000
2500
3400
50
100
10
2605
3411
99466
97451
1. 05
12
4.0
1000
2500
3400
50
100
10
2560
3406
99486
97492
0. 60
13
0
1000
5000
3600
50
50
5
5073
3607
98025
95327
1.47
14
0
1000
5000
4200
50
300
20
5503
4234
95326
97095
1. 68
15
0
1000
5000
4600
50
-50
30
4930
4642
95129
99238
1.40
16
0
1000
6400
600
50
-50
10
6330
614
3589
5214
1.41
17
0
954
6400
1600
50
100
35
6571
1660
6559
99615
1. 71
18
4.0
1000
6400
1800
50
100
10
6488
1809
6352
98680
0.88
19
0
1000
13000
0000
50
500
0
13795
0000
0000
013800
1. 58
20
0
1000
14500
1600
35
400
0
14930
1600
14925
000000
1.06
Unacceptable errors:
When any computed solution contains a northing or easting error greater than 21 meters; when
more than 2 of the 20 solutions contain a northing or easting error greater than 17. 5 meters;
when any C error is greater than 0. 1; or when any two C errors exceed 0. 06.
(1) Place the ∆R handwheel in DETENT.
(2) Set the HR counter to 1, 000 meters.
(3) Set in values of ∆ t, HW, RL, and EL as given in chart II.
Page 217