TM 11-5840-281-12-1
1-10.
LOCATION AND DESCRIPTION OF MAJOR COMPONENTS. (CONT)
INDICATOR POWER SUPPLY
The indicator power supply is located in the bottom-rear of the control-indicator and provides the regulated and
unregulated dc voltages that are used in the control-indicator circuits.
1.11.
EQUIPMENT DATA.
OVERALL SYSTEM
Range (display)
Minimum
5 nmi (9 km)
Maximum
40 nmi (74 km)
IFF (maximum)
80 nmi (148 km)
Precision
30 degrees and 60 degrees
Search
360 degrees
-1 degree to + 10 degrees or - 1 degree to
+ 35 degrees
200 kw nominal
Receiver Minimum Discernible Signal (MDS)
Wide Pulse
- 107 db
Narrow Pulse
-101 db
Input Power
Operates from a 120/208v + 10 percent,
400 Hz 5 percent, 4 kw 3-phase
primary power source
Installation time
Single runway installation with
Approximately 8.5 task-hours
partially assembled equipment
Single runway installation with packed
Approximately 15 task-hours
and crated equipment
1-8