TM 11-5840-281-12-1
1-11.
EQUIPMENT DATA. (CONT)
RECEIVER (DUAL CONVERSION) (CONT)
Noise figure
10 db max
Dynamic range
60 db (ref to input + 1 to + 6 v)
Gain control amplifier
Power gain - wide band
- narrow pulse
7 + 1 MHz
- narrow pulse
2 + 0.5 MHz
60 MHz
Noise figure
10 db max
Gain control range
60 db min
If gain-linear
60 db min at 60 MHz
Small signal gain log
70 db min at 60 MHz
7 + 1 MHz
60 + 0.5 MHz
Noise figure
10 db max
If delay line
Delay
0.24 s
50 ohms
8db max
GaAs fet amplifier
Gain at 9 GHz to 9.6 GHz
20 +3 -Odb
points
600 MHz min
Noise figure
4 db max
Frequency range
Tunable 9 to 9.6 GHz
CONTROL-INDICATOR GROUPS
General
Number of control-indicator groups
Two, one master and one slave
(indicators)
Indicator presentation
Ppi or beta scan can be selected on both
indicators in SEARCH and NORM modes, re-
spectively; ppi display on slave indicator
and beta display on master indicator in
SIMULT mode only.
Remoting
Separation between control-indicator and
or less.
Surveillance
Type of display
Ppi (10 in. (25 cm) dia crt)
Ranges
Linear (5, 10, 20, and 40 nmi (9, 19, 37,
and 74 km) sweeps), 80 nmi (148 km) sweep
for IFF video presentation only
Offset ranges
Full radius on all ranges
Range marks
1 nmi (1.9 km) spacing on 5 and 10 nmi (9
and 19 km) sweeps, 5 nmi (9 km) spacing on
20 and 40 nmi (37 and 74 km) sweeps; 10
nmi (19 km) spacing on 80 nmi (148 km)
sweep
Range mark accuracy
+ 2 percent
Deflection
Rotating coil
1-10