TM 11-5840-281-12-1
2-5. PRELIMINARY OPERATING PROCEDURE. (CONT)
TURN-ON PROCEDURE (CONT)
CAUTION
Ensure that all controls, switches, and circuit breakers are in the positions indicated in
Preliminary Control Settings (para 2-4) before starting the power generator, or damage could
result to the radar equipment.
Make sure filter hood on receiver-transmitter is open and red vent covers on control-
indicators and receiver-transmitter, along with red cover on azimuth drive reducer, are
removed before applying power to the equipment or damage could result to equipment.
NOTE
When radar set is used in conjunction with landing control system shelter, refer to TM 11-
5895-474-12 addendum for information on circuit breakers that power the radar set.
RECEIVER-TRANSM ITTER
1.
Place MAIN PWR circuit breaker (1) to ON position.
2.
Place AC OUTLETS circuit breaker (2) to ON position.
3.
Place HV switch (3) to ON position.
4.
Place SCAN switch (4) to ON position.
5.
Open filter hood (5) on receiver door (6).
2-14