TM 11-6625-1831-13
4-5. DESCRIPTION OF ELECTRICAL TEST PANEL (Cont)
ELECTRICAL TEST PANEL SCHEMATIC DIAGRAMS
A schematic diagram of the test set, including all repairable electrical assemblies, is on a foldout page (figure FO-1)
located at the end of this manual.
4-6. DESCRIPTION OF CABLE ASSEMBLIES
This list describes cables used with the component test set. Each end of each cable is marked with its connection point.
Cable Assembly W1 - 22-wire cable, 72 inches long. Ends are marked P1 and 3P1.
Cable Assembly W2 - 41-wire cable, 72 inches long. Ends are marked P2 and 3P2.
Cable Assembly W3 - 4-wire cable, 36 inches long. Ends are marked P1 and P4.
Cable Assembly W4 - 2-conductor coaxial cable, 36 inches long. Ends are marked P5 and P14.
Cable Assembly W5 - 2-conductor coaxial cable, 36 inches long. Ends are marked P7 and P9.
Cable Assembly W6 - 2-conductor coaxial cable, 36 inches long. Ends are marked P9 and P5
Cable Assembly W7 - 2-conductor coaxial cable, 72 inches long. Ends are marked P1 and P2.
Cable Assembly W8 - 2-conductor coaxial cable, 72 inches long. Ends are marked P1 and P2
Cable Assembly W9 - 2-conductor coaxial cable, 72 inches long. Ends are marked P1 and P2.
Cable Assembly W10 - 2-conductor coaxial cable, 72 inches long. Ends are marked 1P26 and 3P4.
Cable Assembly W1l 2-conductor coaxial cable, 72 inches long. Ends are marked 1P25 and 3P11.
Cable Assembly W12 2-conductor coaxial cable, 72 inches long. Ends are marked 1P7 and 3P9
Cable Assembly W13-2-conductor coaxial cable, 72 inches long. Ends are marked 1P27 and 3P10
Cable Assembly W14-2-conductor coaxial cable, 72 inches long. Ends are marked 3P3 and 3P13
ELECTRICAL DESCRIPTION
Coaxial cables The center conductor and shield each have continuity from one connector to the other
Multiple conductor cables Each pin in one connector has continuity to the pin having the same number In the other
connector.
4-12