TM 11-6625-1831-13
5-3c.
Troubleshooting Break Out Box (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 1.
Check resistor R1. Measure resistance; should be 100 ohms.
Replace if defective (para 5-10).
Step 2.
Check wiring.
Step 1.
Check resistor R2. Measure resistance; should be 100 ohms.
Replace if defective (para 5-10).
Step 2.
Check wiring.
Step 1.
Check resistor R3. Measure resistance; should be 100 ohms
Replace if defective (para 5-10).
Step 2.
Check wiring.
Step 1.
Check resistor R4 Measure resistance; should be 100 ohms.
Replace if defective (para 5-10).
Step 2.
Check wiring.
Check wiring Measure resistance from 3P15-A to ground (test box housing), and from E1 to ground
Both readings should be zero ohms.
5-40