TM 11-6625-847-45
Step
Control setting and operation of
No.
Operation of test procedure
equipment under test
Performance standard
5
Connect the dc test
Set the AGC OFF/ON switch
Measured voltage
leads of the
on tray A1A1 to ON.
varies from 0
ME-26(*)/U to AGC
Rotate the AGC ADJ con-
to -33 2 volts
test points TEST
trol from fully counter-
dc.
and ground on tray A1A1.
clockwise to fully clockwise.
6
Measure the dc voltage
Measure voltage is + 20 1
at NOISE BLANKER
volts dc.
20 VDC test point on
tray A1A1 using ME-
26(*)/U.
7
Rotate the MC FREQ 10MC
Mc shaft coupler on tray A1A1
rotates, indicating the 28 posi-
switches 01 the test set from
tions selected.
2.0 mc to 29.0 mc in 1-mc
steps.
8
Disconnect the ME-
Reset all switches and controls
POWER indicators on the test
26(*)/U.
to the settings, listed in para-
set and common module tray
A1A1 are extinguished.
5-10. Common Module Tray A1A2, Preliminary Switch and Control Settings
Switch or control
Setting
Switch or control
Setting
POWER switch .................... OFF
RF GAIN control ................Fully counterclockwise
RCVR AUDIO section:
XMTR IF AND AUDIO
SQUELCH switch ............ OFF
section:
SQUELCH SYNC
OFF
ALC APC PPC
switch.
CONTROL:
AUDIO GAIN con-
Fully counterclockwise
ALC switch....................OFF
trol.
ALC/PPC SEL
OFF
RCVR IF section:
switch.
AGC SYNC switch........... OFF
POWER CON-
Fully counterclockwise
RF-AGC ON/OFF
OFF
TROL.
switch.
CE MODES
PUSH TO TALK
TEST SELECTOR
1
switch.
switch.
TEST SELECTOR
1
BFO TONE control............... Fully counterclockwise
switch.
5-11. Common Module Tray A1A2, Operational Performance Test
Step
Control setting and operation of
No.
Operation of test procedure
equipment under test
Performance standard
1
Remove common on module tray
A1A2 from the case 2, and
secure it to the test set.
2
Make sure that +27-
Set the switches and controls on
volt dc primarily power
the test set to the settings
is supplied to the
POWER connector
the switches and controls on
on the test set.
common module tray A1A2
to the settings listed in para-
graph 5-10.
3
Set the POWER switch on the
POWER indicator is illuminated
test set to ON.
on the test set.
Change 2 5-5