Volume 1
MIL-HDBK-162A
Section 1
15 December 1965
ITEM NAME: RADAR SET
TYPE: AN/IPX-7A
INSTALLATION CONSIDERATIONS
TECHNICAL DESCRIPTION
Siting: The location of Radar Set
AN/UPX-7A should be such that Antenna
channels
AS-133/APX can be mounted so that it
Center Frequencies:
will have approximately a line-of-sight
Channel 1 - 952 mc
path to the pre-flight test location,
Channel 2 - 969 mc
and high enough to furnish an open
Channel 3 - 986 mc
space for in-flight testing.
Channel 4 - 1003 mc
Mounting: If bench testing is to be
Channel 5 - 1020 mc
done, provision for spacing the antenna
Channel 6 - 1037 mc
of the AN/APX-6 at least ten feet from
Channel 7 - 1054 mc
that of the AN/UPX-7A should be made.
Channel 8 - 1071 mc
If only pre-flight or in-flight tests
Channel 9 - 1068 mc
are to be performed, it may I)e desirable
Channel 10 - 1100 mc
to install the set in a vehicle or
Channel 11 - 1122 mc
trailer.
Channel 12 - 1139 mc
Output Signal:
Cabling Requirements: The length of
Coded rf pulse-pairs spaced -
3 usec apart in Mode 1
RT-19BA/UPX-7 to the AS-133/APX
5 usec apart in Mode 2
should be kept under twenty feet.
8 usec apart in Mode 3
Related Equipments: Used with, but not
Power Output: 24 to d0 db above one
part of AN/APX-6. Indicator ID-169A/
into 51-ohm essentially resistive
APN-12, ID-169B/APN-12, BC-929-A or
load.
BC-929-C may be used in lieu of Indi-
Selectivity: Between 9.5 and 1,1.5 mc
cator ID-169/APN-12 and Mounting
MT-362A/A may be used in lieu of Mount-
response.
ing MT-362/A, depending upon applica-
Power Requirements, ac: 105 to 124Iv,
tion and availability.
320 to 1760 cps; 220 w at 115v
Power Requirements, dc: 2.1 to 29v; 10 w
at 27.5v
PRINCIPAL COMPONENTS AND PHYSICAL DATA
COMPONENT
QTY
HEIGHT
WIDTH
DEPTH
UNIT WT.
(Inches)
(Inches)
(Inches)
Control Panel C-771A/UPX-7
1
3
5-3/-4
4-9/16
2
1
3-3/16
9-7/16
7-1/4
1.1
1
2-3/8
11-1/2
9-1/2
3.5
MT-362A/A
Mounting for Indicator FT-,109-A
1
2-3/8
8-5/8
15-11/16
2
or suitable mounting for
equivalent Indicator
1
12-7/16
13-3/16
9-7/8
73.4
RT-198A/UPX-7
Indicator BC--929-C or equivalent
1
8-7/8
8-3/4
16-3/8
21.6
REFERENCE DATA AND LITERATURE
Nomenclature card for AN/UPX-7A
TECHNICAL ORDER:
33A1-3-1.3- Series
AN/UPX-7A: 2