TM 11-5840-281-12-1
4-23.
INTERCONNECTING CABLES. (CONT)
Interconnecting cables are installed after radar set has been assembled and installed. See FO-1, the Interconnecting
cable diagram, when Installing interconnecting cables. The lengths of cables W3001, W3002, and W3005 will permit a
maximum distance of 250 feet (76 m) between receiver-transmitter and master control-indicator. Ac power cables
W3003 and W3004 are 135 feet (41 m) long and will permit receiver-transmitter and master control-indicator to be
separated a maximum of 135 feet (41 m) each from ac power distribution box. Cables W9501, W9502, W9503, and
W9504 connect master control-indicator to slave control-indicator and are each 25 feet (7.5 m) long. Ac power cable
W3007 is 8 feet (2.5 m) long and connects ac power source to ac power distribution box.
INTERCONNECTING CABLE IDENTIFICATION
The table below identifies Interconnecting cables and their connection points on the associated equipment.
FROM
TO
CABLE
EQUIPMENT
JACK
CABLE
EQUIPMENT
JACK
PLUG
PLUG
CABLE
W3001
Receiver-Transmitter
J104
P104
Master Control-
J604
P604
W3002
Receiver-Transmitter
J102
P102
Master Control-
J602
P602
W3003
Receiver-Transmitter
J101
P101
AC Power Distribution
J9601
P9601
Box
W3004
AC Power Distribution
J9602
P9602
Master Control-
J601
P601
Box
Indicator
W3005
Receiver-Transmitter
J103
P103
Master Control-
J603
P603
W3006
Receiver-Transmitter
E101
---
Grounding Rod
---
---
W3007
AC Power Distribution
J9603
P9603
AC Power Source
---
---
W9501
Master Control-
J605
P605
Slave Control-
J601
P601A
Indicator
Indicator
W9502
Master Control-
J606
P606
Slave Control-
J602
P602A
Indicator
Indicator
4-46