TM 11-5840-281-12-1
4-28. CIRCUIT ALINEMENT. (CONT)
WARNING
To prevent exposure to hazardous rf radiation, ensure no personnel are within an 80- foot
(24.5 m) radius of radar site before performing step 12.
12.
On master control-indicator, place TRANSMITTER switch to WIDE PLS position and press HV ON indicator
switch.
13.
If necessary, adjust applicable PREC DELAY control on pulse generator so td range mark passes through
leading edge of td bracketing simulator returns (or td-rpl target simulator return when used).
14.
On master control-indicator, place TRANSMITTER switch to OFF position.
15.
On pulse generator, set ART ANGLE V control for 2-mile intercept setting recorded in step 8.
16.
Set ALTITUDE control to indicate field elevation plus 300 feet in ALTITUDE indicator window.
17.
Alternately place ANGLE VOLTS switch on pulse generator in EL and OPERATE positions. Adjust HF1 control
to position height finder cursor (1) at intersection of artificial sweep (2) and 2-mile range mark (3).
18.
On pulse generator, place RANGE MILES switch to 20 position.
19.
Set ALTITUDE control on pulse generator to indicate field elevation plus 15,000 feet in ALTITUDE indicator
window.
4-99