TM 11-6625-1831-13
3-5. ORGANIZATIONAL MAINTENANCE
This task covers:
Cleaning the test set
INITIAL SETUP:
Special Environmental Conditions
Adequate ventilation when using
trichlorotrifluoroethane
Materials/Parts
General Safety Instruction
Clean lint-free cloths
None
Trichlorotrifluoroethane cleaning fluid
small cleaning brush
LOCATION/ITEM
ACTION
REMARKS
WARNING
Adequate
ventilation
should
be
provided
when
using
TRICHLOROTRIFLUOROETHANE. Prolonged breathing of vapor should be
avoided. The solvent should not be used near heat or open flame; the products
of
decomposition
are
toxic
and
irritating.
Since
TRICHLOROTRIFLUOROETHANE dissolves natural oils, prolonged contact
with skin should be avoided. When necessary, use gloves which the solvent
cannot penetrate. If the solvent is taken internally, call a physician immediately.
1. TEST SET
a. Remove dirt, corrosion and
Cloth should be damp but not
Exterior surfaces,
fungus with cloth dampened with
wet.
Extender cards,
trichlorotrifluoroethane.
Break out box
b. Remove moisture with dry
cloth.
2. TEST SET
a. Remove dirt, corrosion and
Cable connectors,
fungus with brush, dampened with
plugs, jacks
trichlorotrifluoroethane if
necessary.
b. Remove moisture with dry
cloth.
3 TEST SET
Remove dirt with dry cloth.
Panel controls
3-6