TM 11-6625-1831-13
5-2b.
Electrical Test of Test Panel (Cont)
LOCATION/ITEM
ACTION
REMARKS
14.
TEST PANEL
a. PUSH TO RESET
Press and release
switch (S10)
b. INTERLOCK FAIL
Check-should be off
Malfunction 6.
indicator.
15.
Function selector
Set to 50 Vdc
DC Output check.
NOTE
When measuring dc voltage, connect + probe to jack with (+), connect - probe to jack with (-).
16.
TEST FIXTURE No.
1
a. Jacks A (+) and E (-)
Check for +28+2 Vdc.
Malfunction 7
b. Jacks B (+) and E (-)
Check for +20+2 Vdc.
Malfunction 7
c. Jacks C (+) and E (-)
Check for +5+1 Vdc.
Malfunction 7
d. Jacks D (-) and E (+)
Check for -5+1 Vdc.
Malfunction 7
17.
TEST FIXTURE No.
3
RGP CYCLE switch
Set to ON.
18. TEST PANEL
BITE CYCLING indicator
Check-should be on
Malfunction 8
(DS2)
19
TEST FIXTURE No.
3
RGP CYCLE switch.
Set to OFF.
20.
TEST PANEL
BITE CYCLING indicator
Check-should be off.
Malfunction 9
21.
TEST FIXTURE No.
3
RANGE DELAY ERROR
Set to ON
switch
5-10