TM 11-6625-1831-13
5-2b.
Electrical Test of Test Panel (Cont)
LOCATION/ITEM
ACTION
REMARKS
36.
TEST PANEL
RANGE DELAY switch
Set to position 30.
37
TEST FIXTURE NO.
3
Jacks d (+) and t (-)
Check for 20 + 2 Vdc.
Malfunction 19
38.
TEST PANEL
RANGE DELAY switch
Set to position 40.
39.
TEST FIXTURE NO 3
Jacks e (+) and t (-)
Check for 20 + 2 Vdc.
Malfunction 19
40.
TEST PANEL
RANGE DELAY switch
Set to position 50.
41.
TEST FIXTURE NO.
3
Jacks f (+) and t (-)
Check for 20 + 2 Vdc.
Malfunction 19
42.
TEST PANEL
RANGE DELAY switch
Set to position 60.
43.
TEST FIXTURE NO.
3
Jacks g (+) and t (-)
Check for 20 + 2 Vdc
Malfunction 19
44.
TEST PANEL
RANGE switch (S3)
Set to position 25.
RANGE switch check
45.
TEST FIXTURE NO.
3
Jacks h (+) and t (-)
Check for 20 + 2 Vdc.
Malfunction 20
46
TEST PANEL
RANGE switch
Set to position 50.
47.
TEST FIXTURE NO.
3
Jacks i (+) and t (-)
Check for 20 + 2 Vdc.
Malfunction 20
48.
TEST PANEL
RANGE switch
Set to position 100.
49.
TEST FIXTURE NO.
3
Jacks j (+) and t (-)
Check for 20 + 2 Vdc.
Malfunction 20
50.
TEST PANEL
Set to LEFT.
51.
TEST FIXTURE NO.
3
Jacks q (+) and t (-)
Check for 20 + 2 Vdc.
Malfunction 21
52.
TEST PANEL
ANTENNA switch
Set to BOTH.
53.
TEST FIXTURE NO.
3
Jacks M (+) and t (-)
Check for 20 + 2 Vdc.
Malfunction 21
5-13