TM 11-6625-1831-13
5-2b.
Electrical Test of Test Panel (Cont)
LOCATION/ITEM
ACTION
REMARKS
26.
TEST PANEL
a BITE GO indicator
Check - should be off.
Malfunction 12
b. BITE NO/GO
Check - should be on.
Malfunction 13
indicator (DS4)
27.
TEST FIXTURE NO. 3
RGP FAULT switch
Set to OFF.
28.
TEST PANEL
a. BITE NO/GO
Check - should be off.
Malfunction 14
indicator
b. BITE GO
Check - should be on.
indicator
c. PANEL LIGHTS
Press and hold.
TEST switch (S9)
d. All indicators
Check - should be on.
Malfunction 15, 16
e. PANEL LIGHTS
Release.
TEST switch
f. PWR ON, BITE
Check - should remain
Malfunction 16. 17
GO indicators
on.
g. All other indicators
Check - should be off.
Malfunction 18
29.
Set to 50 Vdc scale.
30.
TEST PANEL
RANGE DELAY
Set to position 0
RANGE DELAY switch check
switch (S2).
31.
TEST FIXTURE
NO 3
Jacks a (+) and t (-)
Check for 20 + 2 Vdc.
Malfunction 19
32.
TEST PANEL
RANGE DELAY switch
Set to position 10.
33.
TEST FIXTURE NO. 3
Jacks b (+) and t (-)
Check for 20 + 2 Vdc.
Malfunction 19
34.
TEST PANEL
RANGE DELAY switch
Set to position 20.
35.
TEST FIXTURE NO. 3
Jacks c (+) and t (-)
Check for 20 + 2 Vdc.
Malfunction 19
5-12