TM 43-6625-916-12
RADAR TEST SET
0002 00
EQUIPMENT DESCRIPTION AND DATA - Continued
If the interrogator was tested by directly coupling to the antenna cable the following is evaluated.
Pulse Power1,3,5
30 dBm MIN
82 dBm MAX
If the interrogator was tested by a radiated over-the-air measurement, the following is evaluated.
Pulse Power1,3
30 dBm MIN
82 dBm MAX
If the interrogator was tested over-the-air, received power is measured by the TS-4530/UPM and corrected for
distance path loss.
EQUIPMENT MARKINGS
The following markings may appear on the TS-4530/UPM equipment:
Direct current. This symbol indicates that the equipment requires direct current input.
Alternating current. This symbol indicates that the equipment requires alternating current
input.
either ac or dc input at the same connector.
3
phase ac input.
Earth (ground) terminal. This symbol indicates the ground (earth) terminal.
Protective conductor terminal. This symbol indicates the protective ground (earth)
terminal.
Frame or chassis terminal. This symbol indicates the frame or chassis terminal for
connection to ground.
Equipotentiality. This symbol indicates an equipotentiality terminal.
On (Supply). This symbol indicates that the power line switch is ON.