TM 11-5840-281-35/1
Figure 5-4. Azimuth Antenna AS-1292/TPN-8 and yoke, exploded view.
reflector and the pins installed as part of the
NOTE
Scope mount (24) and mounting bracket (25)
must be recalibrated to reflector before use in
(6) Install plug (41) in reflector.
installation phase of the radar set.
(7) Attach clamp (10) on polarizer support (39)
using nut (6), screw (7), lockwasher (8), and flat washer
(5) Attach clinometer mount (20) to reflector (40)
(9).
using three screws (16), lockwashers (17), flat washers
(8) Attach identification plate (34) to polarizer
(18), and two pins (19).
support (39) using four nuts (30), screws (31),
lockwashers (32), and flat washers (33).
NOTE
(9) Attach actuator support (47) to yoke (72)
If the clinometer mount (20) has been previously
calibrated to this reflector, insert pins (19) in the
washers (46).
predrilled holes. If a new clinometer mount is
(10) Attach clamp (15) to actuator support
being installed, it must be calibrated to the
5-6