TM 11-6625-1831-13
2-1.
DESCRIPTION AND USE OF OPERATORS CONTROLS AND INDICATORS (Cont)
1 SEC MARK J20 jack - 1 second mark signal from
signal processor
30 SEC MARK J21 jack - 30 second mark signal
from signal processor
unit antenna gate signal from signal processor
ANT GATE IND J23 jack - Indicator unit antenna
gate signal from signal processor
ANT BOTH J16 jack - Signal from signal processor
FT ENABLE J17 jack - Fixed target enable signal
from signal processor
MT ENABLE J18 jack - Moving target enable signal
from signal processor
ECCM SCOPE SYNC J19 jack - Trigger signal for
PREVIDEO GATE J12 jack - Prevideo gate signal
from signal processor
YOKE CLAMP J13 jack - Yoke clamp signal from
signal processor
DEAD TIME GATE J14 jack -- Dead time gate
signal
from signal processor
ECCM MT OUT J15 jack - Simulated moving target
signal output to signal processor
2-2.
SERVICE UPON RECEIPT
Use this procedure to check out new equipment when it is received.
a.
To unpack the test set, follow the unpacking instructions in paragraph 2-4.
b. Inspect the equipment for damage incurred during shipment.
If the equipment has been damaged, report the
damage on SF 364, Report of Discrepancy (ROD).
c. Check the equipment against the packing slip to see if the equipment is complete. Report all discrepancies in
accordance with the instructions of TM 38-750.
d. Check to see whether the equipment has been modified. Check DA PAM 310-4 for any MWO's that should be
installed.
e. If possible, make sure that test set operates by using it to test a signal processor that is known to be good (refer to
applicable technical manual, Appendix A, for signal processor test procedures).
2-5