TM 11-6625-1831-13
5-2b.
Electrical Test of Test Panel (Cont)
LOCATION/ITEM
ACTION
REMARKS
89.
No. 2
a. Power switch
Set to ON.
b. Output
Set for 166s, 4V pulse, 1333s
cycle time.
quency counter to set output.
90.
POWER SUPPLY
a. Output connections
Disconnect from test fixture No. 3
jacks A and K
Connect to test fixture No. 3
+5 VDC and GND
jacks.
b. Power switch
Set to ON.
Set to +5.0 0.1 Vdc.
c. Output voltage
91.
TEST PANEL
a. PWR switch
Set to ON.
b. MT GEN switch (S12)
Set to ON.
c. RANGE switch
Set to position 25.
d. X SELECT switch (S1)
Set to position 3.
e. Y SELECT switch (S15)
Set to position 3.
Set to RIGHT.
g. TARGET WIDTH switch
Set to position 10.
(S13)
92.
a A input
Connect to SWP GATE IN jack J9.
Set to 2 V/cm.
b. B input
Connect to TRIG OUT jack J10.
Set to 5 V/cm.
c. Sweep time
Set to 10 s/cm
5-17