TM 11-6625-1831-13
5-2b.
Electrical Test of Test Panel (Cont)
LOCATION/ITEM
ACTION
REMARKS
93.
TEST PANEL
a. SWP GATE IN J9 jack
Measure time from leading edge
of this signal to leading edge of
signal at TRIG OUT jack - should
be 60 0.4 s. See illustration.
b. TARGET WIDTH switch
Set to position 140.
c. SWP GATE IN J9 jack
Measure time from leading edge
of this signal to leading edge of
signal at TRIG OUT jack - should
be 56 + 0.5 s. See illustration.
d. TRIG OUT J10 jack
Measure time interval between
leading and trailing edges should be
(28 0.5s)
e. TARGET WIDTH switch
Set to position 10.
f. TRIG OUT J10 jack
Measure time interval between
leading and trailing edge-should be
2.0 0.3 s. See illustration.
94.
Set pulse width to 669.6 s.
NO. 2
95.
TEST PANEL
a. RANGE switch
Set to position 100.
b. TRIG OUT J10 jack
Measure time interval between
leading and trailing edges - should
be 4.0 0.3 s.
5-18