TM 11-6625-1831-13
5-3b.
Troubleshooting Test Panel (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 2.
Check wiring. Test for open circuit from +20 volt line XA3-E to S5-2 Test for open circuit from
S5-1 to SIGNAL J2 jack J2-H.
23. Voltage present with PRF switch in RANDOM position.
Replace PRF switch S5.
24. Open circuit through CORNER switch.
Step 1.
Check switch S6 for open circuit. Test continuity from CORNER switch terminals S6-1 to
S6-2.
Step 2.
Check wiring. Test for open circuit from +20 volt line XA3-E to S6-2 Test for proper circuit from
S6-1 to SIGNAL J2 jack J2-L.
25. Voltage present with CORNER switch in LOW position.
Replace CORNER switch S6.
26. Voltage present with DATA MARK switch OFF.
Replace DATA MARK switch S7.
27. Open circuit through DATA MARK switch.
Step 1.
Check switch S7 for open circuit. Push and hold switch S7 Test continuity from S7-1 to S7-3
Step 2.
Check wiring. Test for open circuit from +20volt lineXA3-EtoS7-1. Test for open circuit from
S7-3 to SIGNAL J2 jack J2V.
28. Voltage present with BITE TEST switch OFF.
Replace BITE TEST switch S8.
5-33