TM 11-6625-1831-13
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
12. BITE GO indicator fails to turn off.
Step 1.
Check Oscillator and Switch Module 1A2 by replacing it.
Step 2.
Check wiring. Test for a short circuit to ground between test set ground (XA2-15) and XA2-U
(output to BITE GO indicator).
13. BITE NO/GO indicator fails to light.
Step 1.
Check indicator by replacing it.
Step 2.
Check Oscillator and Switch Module 1A2 by replacing it.
Step 3.
Check wiring. Test for open circuit between XA2-T and BITE NO/GO indicator
14. BITE NO/GO indicator fails to turn off.
Check Oscillator and Switch Module 1A2 by replacing it.
15. Indicators fail to light (except PWR ON).
Step 1.
Check PANEL LIGHTS TEST switch. Press and hold PANEL LIGHTS TEST switch S9. Test
for continuity between terminals 2 and 3 of the switch.
Step 2.
Check Oscillator and Switch Module 1A2 by replacing it.
Step 3.
Check indicator by replacing it.
Step 4.
Check wiring. Test continuity between XA2 and indicator. See schematic for pin number.
16. PWR ON indicator fails to turn on.
Step 1.
Check indicator by replacing it.
Step 2.
Check wiring. Test for open circuit between XA3-H and one terminal of PWR ON indicator.
Also test between the other indicator terminal and test set ground.
5-31