TM 11-6625-1831-13
5-3B.
Troubleshooting Test Panel (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 2.
Check transformer T1 outputs. Check for 26 +8 Vac between T1 terminals 4 to 5, 5 to 6, and 4
to 6 (used for +28 Vdc and +20 Vdc supplies). Check for 7.4 + 1.5 Vac between T1 terminals 7 to
8, 8 to 9, 7 to 9 (used for +5 Vdc supply). Check for 8.1 +0.8 Vac between T1 terminals 10 to 11.
11 to 12, 10 to 12 (used for -5 Vdc supply).
A. If all readings are correct, check for open circuit between T1 and XA3 connector
See schematic for pin numbers.
B. If any reading is not correct, go to step 3.
Step 3.
Check inputs to T1. Check for 200 Vac between T1 terminals 1 to 2, 1 to 3, and 2 to 3.
A.
B.
If any reading is not correct, check for break in wiring between filters FL1, FL2,
8. BITE CYCLING indicator fails to turn on.
Step 1.
Check indicator by replacing it.
Step 2.
Check Oscillator and Switch Module 1A2 by replacing it.
Step 3.
Check for open circuit in wiring. Test continuity from XA2-16 to BITE CYCLING indicator.
Test continuity from XA2-17 to pin C of SIGNAL J2 jack.
9. BITE CYCLING indicator fails to turn off.
Check Oscillator and Switch Module 1A2 by replacing it.
10. RANGE/DELAY ERROR indicator fails to turn on.
Step 1.
Check indicator by replacing it.
Step 2.
Check Oscillator and Switch Module 1A2 by replacing it.
Step 3.
Check wiring. Test continuity from XA2-R to RANGE/DELAY ERROR indicator. Test
continuity from XA2-5 to pin r of SIGNAL J2 jack.
11. RANGE/DELAY ERROR indicator fails to turn off.
Check Oscillator and Switch Module 1A2 by replacing it.
5-30