TM 43-6625-916-12
RADAR TEST SET
0007 00
Table 7-1. Battery Charger Controls, Indicators, and Connectors
Item
Control / Indicator / Connector
Function
1
Battery Compartment
Holds battery stick or batteries while charging
2
DISCHARGE START Switch
Press to initiate battery discharge
3
Discharge LED
Red LED indicates battery stick or batteries being
discharged
4
Charge LED
Flashing yellow LED indicates battery stick or batteries
being charged
5
DC input
AC adapter (PN: 15-0360-M0) connects here
Battery Charging Using External Charger/Discharger
Use only with battery sticks or commercial C-size NI-CAD or NiMH
rechargeable batteries.
Only use when temperature of charger and batteries is between 0 and 40
degrees C.
Do not short positive and negative terminals together when handling NI-CAD
or NiMH batteries. The battery cells may EXPLODE and cause INJURY or
DEATH.
Indoor use only. Do not expose charger or AC adapter to rain or moisture.
Use only 12 V dc, 2 Amp minimum, 4 Amp maximum voltage regulated
power source.